They ensure that gas can be used safely at all times. The DVGW Code of Practice is compulsory reading for gas suppliers, tradesmen, plumbers, engineers and anyone who deals professionally with the subject of natural gas.
The regulations in this Guideline G 451 shall be observed when planning and constructing gas transmission pipelines in conjunction with statutory procedures such as regional planning procedures und planning permission hearings.
This Standard shall also apply, mutatis mutandis, to gas mixing plants that supply process gas to trade and industry and to industrial gas mixing plants for in‑house mixed‑gas supply.Gas mixing plants are frequently integrated into gas measurement and pressure reduction stations, which latter shall meet the specifications of DVGW Standards G 491 and G 492. In other words, most of the requirements specified in these Standards will also apply to gas mixing plants. All other requirements that go beyond the scope of G 491 and G 492 are described in this Technical Rule at hand, which first and foremost complements DVGW Standard G 491.
This DVGW Standard can be used as a guideline as it summarises the minimum requirements specified in the DVGW Sets of Rules that shall be observed by design firms, specialist contractors, operators and the involved authorities during the design, construction and operation of gas pipework for the transmission of untreated or partially treated biogas. The clause on Design also draws attention to the fact that the pertinent approvals and / or permissions shall be obtained prior to the start of construction of pipework planned to cross e. g. water bodies, roads and railways.Gases produced by fermentation processes such as e. g. biogases obtained from agriculture that are generally used to meet internal requirements and / or to power decentralised systems such as e. g. combined heat and power plants, are untreated or partially treated biogases that are not considered gases in accordance with DVGW Standard G 260.Nonetheless, the documents that form part of the DVGW Set of Rules that are referred to in this Standard shall also be applied to pipelines that transmit untreated or partially treated biogas.
The aim of this Standard GW 368 is to determine the lengths of pipeline to be locked against longitudinal forces.The Worksheet applies to ductile cast iron and steel pipes, fittings and valves. In principle, the formulaic correspondences described can also be applied to pipes in other materials. However, the properties of the other materials must be taken into account in each case, particularly specific weight and friction coefficient.
The Instruction Bulletin G 501 defines the requirements and test criteria applying to remote gas detection integrated aboard aircraft (helicopters or airplanes) and designed to aerially monitor both buried natural gas transmission pipelines as well as above ground natural gas transmission pipelines that are suited for airborne remote gas detection, both inside and outside built‑up areas. Portable hand‑held measuring instruments or methods combined with motor vehicles shall not be dealt with in this paper, as due to their flat observation angle to the surface compared to detection from the air they are subject to modified requirement criteria.
This Code of Practice G 402 has been elaborated by the G 401 project group within the Technical Committee on Gas distribution. It shall serve as a basis for the collection and evaluation of data to devise maintenance strategies for gas distribution systems. Maintenance comprises inspection as well as service and repair activities. The respective DVGW Codes of Practice define the fundamental principles applying to inspection and service activities. This Code of Practice G 402 focuses on the collection and evaluation of data that form the main basis for repair planning. The requirement for gas distribution systems to be permanently kept in a condition guaranteeing their technical safety and reliability necessitates timely and ongoing maintenance and service activities. These activities shall be planned in advance. Maintenance strategies shall be integrated into corporate processes, the collection of major grid data being a prerequisite for introducing such strategies. Beyond this, condition‑based maintenance requires ascertaining and evaluating grid conditions by means of adequate systems. This Code of Practice describes the fundamental procedure for ascertaining, collecting and evaluating maintenance‑relevant data and offers examples illustrating how to prepare and evaluate them.
Funktionale Cookies sind für die Funktionalität des Webshops unbedingt erforderlich. Diese Cookies ordnen Ihrem Browser eine eindeutige zufällige ID zu damit Ihr ungehindertes Einkaufserlebnis über mehrere Seitenaufrufe hinweg gewährleistet werden kann.
Session:
Das Session Cookie speichert Ihre Einkaufsdaten über mehrere Seitenaufrufe hinweg und ist somit unerlässlich für Ihr persönliches Einkaufserlebnis.
PayPal-Zahlungen
Google-Pay-Zahlungen
Mollie Payment:
Dieses Cookie wird verwendet, um alle Ereignisse zu gruppieren, die von einer einzelnen Benutzersitzung auf mehreren Checkout-Seiten generiert wurden.
Cache Behandlung:
Das Cookie wird eingesetzt um den Cache für unterschiedliche Szenarien und Seitenbenutzer zu differenzieren.
Wallee-Zahlungen
Aktivierte Cookies:
Speichert welche Cookies bereits vom Benutzer zum ersten Mal akzeptiert wurden.
Zeitzone:
Das Cookie wird verwendet um dem System die aktuelle Zeitzone des Benutzers zur Verfügung zu stellen.
Google Tag Manager Debug Modus:
Ermöglicht es den Google Tag Manager im Debug Modus auszuführen.
Cookie Einstellungen:
Das Cookie wird verwendet um die Cookie Einstellungen des Seitenbenutzers über mehrere Browsersitzungen zu speichern.
CAPTCHA-Integration
CSRF-Token:
Das CSRF-Token Cookie trägt zu Ihrer Sicherheit bei. Es verstärkt die Absicherung bei Formularen gegen unerwünschte Hackangriffe.
Herkunftsinformationen:
Das Cookie speichert die Herkunftsseite und die zuerst besuchte Seite des Benutzers für eine weitere Verwendung.
Marketing Cookies dienen dazu Werbeanzeigen auf der Webseite zielgerichtet und individuell über mehrere Seitenaufrufe und Browsersitzungen zu schalten.
Bing Ads:
Wird verwendet, um Besucher auf der Website zu identifizieren und deren Verhalten zu verfolgen, um die Effektivität der Werbung zu messen und zu verbessern.
Google Conversion Tracking:
Das Google Conversion Tracking Cookie wird genutzt um Conversions auf der Webseite effektiv zu erfassen. Diese Informationen werden vom Seitenbetreiber genutzt um Google AdWords Kampagnen gezielt einzusetzen.
Google AdSense:
Das Cookie wird von Google AdSense für Förderung der Werbungseffizienz auf der Webseite verwendet.
Tracking Cookies helfen dem Shopbetreiber Informationen über das Verhalten von Nutzern auf ihrer Webseite zu sammeln und auszuwerten.
Bing Ads:
Das Bing Ads Tracking Cookie wird verwendet um Informationen über die Aktivität von Besuchern auf der Website zu erstellen und für Werbeanzeigen zu nutzen.
Google Analytics:
Google Analytics wird zur Datenverkehrsanalyse der Webseite eingesetzt. Dabei können Statistiken über Webseitenaktivitäten erstellt und ausgelesen werden.
Matomo:
Das Cookie wird genutzt um Webseitenaktivitäten zu verfolgen. Die gesammelten Informationen werden zur Seitenanalyse und zur Erstellung von Statistiken verwendet.
Erlaubt es Google, personenbezogene Daten für Online-Werbung und Marketing zu sammeln.
Google Werbung und Marketing
Für Statistiken und Shop-Performance-Metriken genutzte Cookies.
Google Tagmanager
Diese Website verwendet Cookies, um Ihnen die bestmögliche Funktionalität bieten zu können... Mehr Informationen.