Zum Hauptinhalt springen Zur Suche springen Zur Hauptnavigation springen

W 118 Technical Rule - Standard 07/2005 -PDF file-

Dimensioning of vertical filter wells

121,34 €

Mitgliederpreis: 91,00 €

Hrsg./Verlag
DVGW
Material
available as PDF only
Format
24 pages
Ausgabe
1st edition 2005
Hinweis
German version W 118
Artikel-Nr.
510398
Verkaufseinheit
1
Mindestabnahme
1

Sicherheitshinweis entsprechend Art. 9 Abs. 7 S. 2 der GPSR entbehrlich

Produkt Anzahl: Gib den gewünschten Wert ein oder benutze die Schaltflächen um die Anzahl zu erhöhen oder zu reduzieren.
ST
Artikel-Nr. 510398


Co2-neutral gedruckte DVGW-Arbeitsblätter


klimaneutraler Paketversand mit GLS und DHL


Zahlung auf Rechnung


1-3 Tage

This Code of Practice W 118 serves as basis for the hydraulic and mechanical dimensioning of wells. The references listed represent the minimum requirements on the dimensioning of vertical filter wells.

Well dimensioning shall be performed so that a hydraulically effective, functionally reliable and economic water abstraction from the aquifer is guaranteed in the long run. At the same time, apart from the Basic hydrogeological parameters, the operating company's technical specifications and the well construction technology are of importance. A careful selection from the various options in well dimensioning can often minimise problems during later well operation, for instance ageing phenomena.

For the planning specialists in drilling and well construction companies, engineering offices and water utilities, the code of practice shall provide assistance for the hydraulic and static dimensioning of vertical filter wells.

Sicherheitshinweis entsprechend Art. 9 Abs. 7 S. 2 der GPSR entbehrlich

Ausgabe: PDF-Download

This Code of Practice W 118 serves as basis for the hydraulic and mechanical dimensioning of wells. The references listed represent the minimum requirements on the dimensioning of vertical filter wells.

Well dimensioning shall be performed so that a hydraulically effective, functionally reliable and economic water abstraction from the aquifer is guaranteed in the long run. At the same time, apart from the Basic hydrogeological parameters, the operating company's technical specifications and the well construction technology are of importance. A careful selection from the various options in well dimensioning can often minimise problems during later well operation, for instance ageing phenomena.

For the planning specialists in drilling and well construction companies, engineering offices and water utilities, the code of practice shall provide assistance for the hydraulic and static dimensioning of vertical filter wells.

Sicherheitshinweis entsprechend Art. 9 Abs. 7 S. 2 der GPSR entbehrlich

Ausgabe: PDF-Download